Features:
- Charge output with low battery disconnect function
- Light controlled, only a timer
- Two-digit display and seven segments for a quick and easy configuration of the load output function, including the timer setting.
- Battery charge in three stages (constant current, constant voltage, slow charge), non-schedulable.
- Departure of charge protected against overloads and short circuits.
- Reverse polarity protection for solar system and/or battery.
- automatic system voltage detection
- Automatic charge disconnection
Features:
- Battery voltage 12/24 V
- Maximum solar voltage 28 V / 55 V (*1)
- Own consumption
- Charge output: manual control + low voltage off
- Protection: reverse polarity in the battery (functional), short circuit of output, overtemperature
- Overload protection: off after 60 s with a load of 130 %
- Overload protection: off after 5 s to 160 % load
- Overload protection shortcut: off immediately
- Ground: Common Positive Land
- Operating temperature -20 to +50°C (full charge)
- Humidity (without condensation): Max 95%
Battery:
- "constant" load voltage (absorption): 14,2 V / 28,4 V (*2)
- "floating" load voltage (floating): 13,8 / 27,6 V
- Low voltage charge off: 11,2 V/22,4 V
- Reconnection of the charge after low voltage: 12.6 V / 25.2 V (manual) / 13,1 V / 26,2 V (automatic)
*1) To 12 V, use 36-cell solar modules.
A 24 V, use solar modules with 72 cells or 2x 46 serial cells.
*2) 2 hours after reaching constant voltage, the regulator changes to the lowest float voltage level.Each time the battery voltage is less than 13 V, a new charging cycle is activated.